When setting the voltage of the output modules, the input power connector must be attached, and the unit must be powered up.

Be careful not to make contact with the input side of the unit from now on as the unit is live. The input side of the unit should be isolated to ensure safe configuration.
Set the voltage set points using a calibrated multi-meter and a potentiometer adjuster.
The use of shielded test leads with clips prevents accidental shorting of the module terminals and ensures a good connection.
Once these are clipped into place begin adjusting the output voltage to the desired voltage. Turning the potentiometer anti-clockwise decreases the voltage. Turning it clockwise increases the voltage. In the example in our video we are setting the voltage of the OP1 module in Slot A to 5Vdc.
Use the potentiometer adjuster and multi-meter to adjust the other modules to the required voltage.